1.
To activate the function, hold down the TOTAL key
while turning on power to the unit.
The GFX-8 starts to automatically cycle through the factory-
default patches.
The indication "SELF INTRODUCTION" and the currently
selected patch name are scrolled on the display. You can play
your guitar while checking out the various patches.
2.
To stop the self introduction function, press the
EDIT/CANCEL key.
Trying Out the Factory Default Patches (Self Introduction Function)
1.
Turn power to the GFX-8 on while keeping the STORE
key depressed.
The display shows "ALL-INIT".
To perform All Initialize
Continue with the next step.
To perform Factory Recall
Use the BANK UP/DOWN foot switch and foot
switches 1 - 4 to select the patch (from a user group)
that you want to return to the factory default condition.
2.
Press the STORE key once more
All Initialize or Factory Recall is carried out. If All Initialize was
carried out, the unit automatically returns to the play mode.
Note that when All Initialize is executed, the contents of all
patches stored by the user will be overwritten (erased). When
wishing to cancel All Initialize/Factory Recall, press the
EDIT/CANCEL key before step 2.
Other Functions
This section contains information about special functions such as how to return the GFX-8 to the factory default condition and
how to readjust the expression pedal.
41
ZOOM GFX-8
All Initialize/Factory Recall
Other Functions
The All Initialize/Factory Recall function is a special function that lets you reset the GFX-8 to the condition in which it was originally
shipped. When All Initialize is performed, all settings of the unit including all user group patches are returned to the default
condition. Factory Recall can be used to reset only specific user group patches group to the default settings.
The GFX-8 also incorporates a so-called self introduction function that automatically switches patches to demonstrate the
capabilities of the unit.
1.
Hold down the GROUP key while turning on power to
the unit.
The indication "MIN" appears on the display.
2.
With the expression pedal fully raised, press the
STORE key.
The display indication changes to "MAX".
3.
Push the expression pedal down until it touches the
stopper and then release the pedal. Press the STORE
key at this point.
The adjustment is completed, and the unit returns to the play
mode.
Adjusting the Expression Pedal
The expression pedal of the GFX-8 uses a highly reliable optical sensor mechanism. The pedal is adjusted for optimum
operation at the factory, but it can be readjusted as follows If required.
1.
Hold down the MIDI key while turning on power to the
unit.
The display shows "BYP ENTR", and depending on the
current setting, the indication "En" (bypass/mute function
enabled) or "dS" (bypass/mute function disabled) is shown on the
GROUP/BANK indicator.
2.
Use the PARM VALUE knob to select the desired
setting.
3.
Press the STORE key.
The setting is stored and the GFX-8 switches to the play
mode. If you press the CANCEL key instead of the STORE
key, no change is made and the GFX-8 switches to the play
mode.
Disabling the Bypass/Mute Function
If desired, the setup of the unit can be changed so that the bypass/mute condition will not be activated also when the foot switch
with the lit LED is pushed. This can help to prevent inadvertently switching to bypass/mute. To make the setting, proceed as
follows.